Deep Thermal Shock/Fluid Cooling System

Thermal shock cooling systems for dynamic cooling applications involving engine cold start testing, heat exchanger thermal cycling including engine, heater core and radiator and critical process cooling.  Ideal for primary or secondary cooling system applications.  These can include refrigerant to coolant and Brine to coolant systems.  Air cooled and water cooled conditioning systems available.

Features

  • Pressurized feed control
  • Remote set point capability
  • Portable systems available
  • Use as a stand alone unit or integrate with supplemental external Q Corp’ supply modules
  • Data collection and computation through PLC based touch screen, also available through LabVIEW automation software packages
  • Also available as a “boost chiller” for additional cooling capacity to an existing cooling system
  • Operation provides for energy efficient staging of compressor system, high tolerance to varying loads across conditioning coil.

Specs

Temperature Range: -40F to 250F
Conditioned Flow Range: 5 gpm to 150 gpm+
Operation: Stand alone, w/ process water cooling or “boost chill”
Capacity: 60 Hp to 600 Hp

Control: Fully automatic, PLC driven
Control Interface: LabVIEW® software with PC interface